- PolyJet Legacy Printers
- Alaris30 V1
- Connex260
- Connex350/500
- Eden250
- Eden260
- Eden260V/VS
- Eden330
- Eden350
- Eden350V/500V
- J700 & J720 Dental
- J750/J735
- J750 Digital Anatomy
- Objet24/30 V2 Family
- Objet24/30 V3 Family
- Objet30 V5 Pro & Prime
- Objet260 Connex 1-2-3
- Objet260 Dental & Dental Selection
- Objet350/500 Connex 1-2-3
- Objet1000 Plus
- PolyJet Materials
- Agilus30 family
- Biocompatible
- Dental Materials
- Dental TrueDent Materials
- Dental TrueDent-D Materials
- Digital ABS Plus
- Digital Anatomy Materials
- DraftGrey
- Elastico Clear/Black
- High Temperature
- PolyJet Support
- Rigur & Durus
- Tango
- Transparent
- Vero ContactClear
- Vero Family
- Veroflex
- VeroUltra Opaque
- Vivid Colors
- Stereolithography Materials
- Somos® 9120™
- Somos® BioClear™
- Somos® DMX SL™ 100
- Somos® Element™
- Somos® EvoLVe™ 128
- Somos® GP Plus™ 14122
- Somos® Momentum™
- Somos® NeXt™
- Somos® PerFORM™
- Somos® PerFORM Reflect™
- Somos® ProtoGen™ 18420
- Somos® ProtoTherm™ 12120
- Somos® Taurus™
- Somos® WaterClear® Ultra 10122
- Somos® WaterShed® AF
- Somos® WaterShed® Black
- Somos® WaterShed® XC 11122
3D Printed Models with Melted Look
The Walls of the Model Look Melted
Printed models occasionally have a melted look, with the appearance of droplets or drooping on the surface. This can be caused by a number of reasons, which we describe below.
Possible Causes and Solutions
Dirty UV Glass Lens
The glass lens on the UV lamp may be dirty with material.
Solution: Clean the glass with Isopropyl alcohol and a clean cloth.
Preventive measures: Make sure the glass lens on each of the UV lamps is always clean. For easy access, run the Head Cleaning wizard, and use the special cleaning pad supplied. Make sure that the glass over the UV sensor is always clean.
See the User Guide for detailed instructions on how to clean the UV lens.
Low UV Intensity
The UV lamp might flicker, or its intensity might be too low. In this case, it does not cure the material properly, resulting in melted-looking layers.
Solution: Run the UV Lamp Calibration wizard. If the UV lamp cannot be calibrated, you might need to replace the UV lamp. See the user guide for guidelines.
Preventive measures: None.
TIP: In addition to the suggested above, you can also run the Dynamic Nozzle Test as a diagnostic tool if you suspect the nozzles are not working properly.